Academic Research & Graduate Portfolio Prototype for Physiological Signal Processing and Machine Learning
A transparent, leak-free framework bridging historical electrocardiographic signals, decoupled predictive models, and reproducible biomedical engineering.
ECG Insight Lab (CardioSense) is an open-source, software-only research platform developed to investigate reproducible signal conditioning, deterministic feature engineering, and decoupled machine learning models across public electrocardiogram benchmarks.
The platform is architected around three active, mathematically decoupled workflows:
- Workflow 1: 12-Lead ECG Multi-Label Classification (PTB-XL v1.0.3)
Multi-label diagnostic classification across 5 SCP-ECG superclasses (NORM,MI,STTC,CD,HYP) using 148 deterministic waveform features and validation-calibrated decision thresholds on official patient-stratified folds. - Workflow 2: Single-Lead Beat Analysis (MIT-BIH Arrhythmia Database v1.0.0)
Autonomous Pan-Tompkins QRS peak detection, morphological windowing, and 4-class beat classification (N,S,V,Q) evaluated across 21 held-out patient records under strict patient-disjoint partitioning. - Workflow 3: AD8232 Hardware Prototype — Offline Simulation & Acquisition
Self-contained benchtop analog front-end prototyping (AD8232 + Arduino Uno) with line-oriented UART streaming, offline stream simulation, causal digital filtering, and safety guardrails strictly enforcing electrical safety standards (IEC 60601-1).
Note
Archival Status: The Optical Paper Digitizer module has been relocated from the primary navigation and default user experience into an isolated, collapsible archival section. While the classical morphological trace extractor achieves
For comprehensive evaluation by professors, admissions committees, and technical reviewers, see the dedicated research documentation:
- Portfolio Report (docs/PORTFOLIO_REPORT.md) — Executive overview, quantitative achievements, and engineering contributions.
- System Architecture (docs/ARCHITECTURE.md) — Decoupled pipeline topology, data contracts, and safety guardrails.
- Research Methods (docs/RESEARCH_METHODS.md) — Signal conditioning, feature engineering mathematics, leak-free partitioning, and bootstrap protocols.
- Results & Limitations (docs/RESULTS_AND_LIMITATIONS.md) — Full quantitative benchmarks, confusion matrices, failure modes, and honest caveats.
- Single-Lead Imbalance Experiment (docs/reports/single_lead_imbalance_experiment.md) — Controlled study on class imbalance and cost-sensitive minority boosting.
- Changelog (CHANGELOG.md) — Complete chronological audit trail of architectural milestones.
All figures embedded below are genuinely produced from actual project data and reproducible code:
Figure 1: Authentic 10-second 12-lead digital ECG recording (00001_lr) from PTB-XL v1.0.3 sampled at 100 Hz, with physical axes calibrated in seconds and millivolts.
Benchtop verification of the AD8232 analog front-end and real-time UART serial data transmission:
The complete interactive research interface can be observed in real time across the two core platform modes:
Demonstrates interactive 12-lead signal exploration, zero-phase filtering and Bode response, diagnostic superclass inference, confusion matrices, single-lead MIT-BIH Holter beat classification, and LLM clinical explanations.
Demonstrates the 9-step pedagogical walkthrough covering cardiac electrophysiology, data leakage prevention, signal conditioning, decoupled machine learning architectures, and calibrated diagnostic decision cutoffs.
Tip
Click here to watch the full 1080p video in GitHub native video player (docs/assets/demo_guide.mp4).
flowchart TD
subgraph WF_1["Workflow 1: 12-Lead ECG Classification (PTB-XL)"]
B1["PTB-XL v1.0.3 Dataset
(21,799 12-Lead Records, PhysioNet WFDB)"] --> B2["Patient-Clustered Folds
(Folds 1-8: Train | Fold 9: Val | Fold 10: Test)"]
B2 --> B3["Feature Extraction Engine
(148 Deterministic Signal Features)"]
B3 --> B4["Multi-Label Diagnostic Classifier
(One-vs-Rest Logistic Regression + Validated Cutoffs)"]
B4 --> B5["Interactive Explorer & Held-Out Benchmark
(Calibrated mV/s Viewer, Clustered Bootstrap CIs)"]
end
subgraph DECOUPLING["Strict Architectural Boundaries (Decoupling)"]
style DECOUPLING fill:#fff2f2,stroke:#d9534f,stroke-width:2px,stroke-dasharray: 5 5
BOUNDARY["GATED DECISION BOUNDARY
No Paper-to-Digital Classification Bridge
No Single-Lead Heart Attack / MI Diagnosis
No Live Hardware Sensor Claims"]
end
subgraph WF_2["Workflow 2: Single-Lead Beat Analysis (MIT-BIH)"]
C1["MIT-BIH Arrhythmia Database v1.0.0
(48 Records, 47 Patients, 360 Hz)"] --> C2["Patient-Disjoint Splits
(16 Train | 7 Val | 21 Held-Out Test)
Records 201 & 202 strictly co-located"]
C2 --> C3["Autonomous Signal-Based R-Peak Detector
(Pan-Tompkins Filter — Zero Annotations at Inference)"]
C3 --> C4["Feature Extraction & Classifier
(47 Descriptors + Balanced Random Forest)"]
C4 --> C5["Recorded Playback Simulation in Streamlit
(RECORDED DATA REPLAY — NOT LIVE HARDWARE)"]
end
subgraph WF_3["Workflow 3: AD8232 Hardware Prototype & Simulation"]
H1["AD8232 Analog Front-End
(3-Lead Differential Instrumentation Amp)"] --> H2["Arduino Uno ADC Streaming
(115,200 Baud UART, 360 Hz Scheduled Sampling)"]
H2 --> H3["Offline Transport Simulator & Parser
(Frame Validation, Packet Verification)"]
H3 --> H4["Causal Digital Conditioning
(0.5-40 Hz Bandpass, 50 Hz Notch)"]
H4 --> H5["Streamlit Prototype UI
(Persistent Simulation Notice & IEC 60601-1 Guardrails)"]
end
subgraph ARCHIVED["Archived Research Module: Optical Paper Digitizer"]
style ARCHIVED fill:#f9f9f9,stroke:#999999,stroke-width:1px,stroke-dasharray: 3 3
A1["Input: Paper ECG Image
(Synthetic Sample Fixture)"] --> A2["Image Validation Gate
(Dimension, Aspect Ratio, Decompression Guards)"]
A2 --> A3["12-Lead Bounding Box Segmentation
(Standard 3x4 Clinical Layout)"]
A3 --> A4["Morphological Centroid Digitizer
(Classical CPU Baseline)"]
A4 --> A5["Signal Visualization & Data Export
(Relative Units, Unrecovered Calibration)"]
end
ARCHIVED -.->|UNVALIDATED ON REAL SCANS - GATED| BOUNDARY
BOUNDARY -.->|PROHIBITED| WF_1
BOUNDARY -.->|PROHIBITED| WF_2
WF_3 -.->|SIMULATION ONLY - UNCALIBRATED ADC GATED| BOUNDARY
- Strict Subsystem Decoupling:
- Workflow 1 (12-Lead Waveform ML): Digital waveform feature extraction and diagnostic classification across 5 SCP-ECG superclasses (
NORM,MI,STTC,CD,HYP) trained and evaluated on official patient-stratified partitions. - Workflow 2 (Single-Lead Beat Analysis): Single-channel beat-type classification using a project-defined 4-class beat grouping (
N,S,V,Q, with ventricular fusion beatsFmerged intoQ) on MIT-BIH Holter data, autonomous Pan-Tompkins QRS detection, and simulated recorded playback. - Workflow 3 (Hardware Prototype & Offline Simulation): Self-contained firmware, schematics, host protocol, offline simulator, and dedicated Streamlit simulation UI (
Hardware Prototype — Offline AD8232 Simulation) underhardware/. Operates completely offline with simulated 10-bit ADC transport, protocol serialization/parsing, simulator inverse conversion, visible per-beat predictions, and post-hoc reference evaluation. Raw ADC counts are never fed into ML classifiers. - Archived Module (Optical Paper Digitizer): Morphological trace extraction preserved in an isolated collapsible UI section and documented under historical benchmarks.
- Workflow 1 (12-Lead Waveform ML): Digital waveform feature extraction and diagnostic classification across 5 SCP-ECG superclasses (
- Gated Integration Boundary: Optical digitizer outputs and uncalibrated hardware ADC counts are not routed into diagnostic classifiers, and single-lead signals are never used to predict acute coronary syndrome (MI/STTC/CD/HYP).
- Cryptographic Model Trust: Model serialization uses SHA-256 sidecar manifests (
waveform_lr_model.joblib.manifest.json,single_lead_rf_model.joblib.manifest.json). Untrusted legacy pickles are strictly quarantined inlegacy/and rejected by code policy. - Zero-Persistence Privacy: Uploaded images and signals are processed entirely in volatile RAM buffers (
BytesIO). No files, logs, or patient identifiers are ever written to disk or transmitted across networks. - Quiet Academic Editorial Interface: A distraction-free visual environment designed according to research editorial standards (warm ivory
#F7F6F2, deep charcoal#252722, and forest green#455D4A).
Evaluated across all 2,198 records (
| Diagnostic Superclass | Positive Support | Decision Threshold | Precision | Recall | F1-Score | PR-AUC |
|---|---|---|---|---|---|---|
| NORM (Normal ECG) | 963 | 0.50 | 0.6995 | 0.8484 | 0.7668 | 0.8128 |
| MI (Myocardial Infarction) | 550 | 0.50 | 0.4708 | 0.6891 | 0.5594 | 0.5468 |
| STTC (ST/T Changes) | 521 | 0.55 | 0.5173 | 0.7159 | 0.6006 | 0.5856 |
| CD (Conduction Disturbance) | 496 | 0.55 | 0.5581 | 0.6492 | 0.6002 | 0.6671 |
| HYP (Hypertrophy) | 262 | 0.65 | 0.4520 | 0.6107 | 0.5195 | 0.5338 |
| Macro Average | 2,198 | — | 0.5633 | 0.6667 | 0.6093 | 0.6292 |
| Micro Average | 2,198 | — | 0.5828 | 0.7077 | 0.6392 | — |
A paired patient-cluster bootstrap analysis (
-
Pilot Model Macro F1:
$0.4583$ vs. Full-Fold Model Macro F1:$0.6093$ ($\Delta = +0.1510$ ). -
95% Paired Patient-Clustered Bootstrap CI for Difference:
$[+0.1343, +0.1681]$ ($ ext{SE} = 0.0087$).
Note
Taxonomy Disclosure: Project-defined 4-class beat grouping: N, S, V, Q, with ventricular fusion beats (F) merged into Q. This is not a standard five-class AAMI EC57 implementation.
In evaluated non-paced records, 98.2% of Class Q beats are ventricular fusion beats (F) rather than unclassifiable beats. Evaluated across 21 disjoint held-out patient recordings from the MIT-BIH Arrhythmia Database v1.0.0.
Evaluates beat classification on detected R-peaks proposed by the automated Pan-Tompkins detector, matched to reference annotations within
- Signal-Based Detector Performance:
- Total Reference Beats: 47,576
- Total Detected Peaks: 47,163
- True Positives (TP): 47,048 | False Positives (FP): 115 | False Negatives (FN): 528
- Detector Sensitivity: 98.89% | Detector PPV: 99.76% | Detector F1-Score: 99.32%
- Evaluated Detections (Feature-Valid): 47,034 beats (47,048 matched detections minus 14 boundary-truncated beats)
- Primary Accuracy Metrics:
- Macro F1-Score: 0.5274
- Weighted F1-Score: 0.9011
| Beat Class Grouping | True Support | Precision | Recall | F1-Score | Grouping Description |
|---|---|---|---|---|---|
| N | 41,883 | 0.9592 | 0.9218 | 0.9401 | Normal / Bundle Branch Block Beats (N, L, R, e, j) |
| S | 1,757 | 0.3555 | 0.1793 | 0.2384 | Supraventricular Ectopic Beats (A, a, J, S) |
| V | 3,018 | 0.7781 | 0.9298 | 0.8472 | Ventricular Ectopic Beats (V, E) |
| Q | 376 | 0.0489 | 0.2979 | 0.0840 | Ventricular Fusion (F) & Unclassifiable (Q) |
| Macro Average | 47,034 | 0.5354 | 0.5822 | 0.5274 | Unweighted mean across all 4 classes |
| Weighted Average | 47,034 | 0.9178 | 0.8896 | 0.9011 | Prevalence-weighted mean |
Note
Benchmark Interpretation Note: Matched-detection conditional beat-classification metrics — classification F1 is calculated only for detector peaks matched to a reference annotation and retained after feature-window boundary checks. Detector false positives (115 peaks) and missed reference beats (542 beats, including boundary-dropped matched beats) are reported separately in detector/count-reconciliation metrics and are not included as errors in this classifier confusion matrix.
Isolates classifier feature discrimination assuming ideal QRS localization (centred on expert ground-truth annotation indices; 47,561 valid windows after dropping 15 boundary reference annotations):
| Beat Class Grouping | Reference Support | Precision | Recall | F1-Score | Baseline F1 |
|---|---|---|---|---|---|
| N (Normal / BBB Beat) | 42,184 | 0.9595 | 0.9247 | 0.9418 | 0.9401 |
| S (Supraventricular Ectopic / PAC) | 1,782 | 0.4035 | 0.2043 | 0.2712 | 0.0000 |
| V (Ventricular Ectopic / PVC) | 3,201 | 0.7912 | 0.9222 | 0.8517 | 0.0000 |
| Q (Ventricular Fusion & Other) | 394 | 0.0549 | 0.3173 | 0.0936 | 0.0000 |
| Macro Average | 47,561 | 0.5523 | 0.5921 | 0.5396 | 0.2350 |
| Weighted Average | 47,561 | 0.9192 | 0.9002 | 0.9036 | 0.8338 |
A controlled experiment was conducted evaluating 4 candidate strategies on patient-disjoint splits to tackle minority class degradation without test peeking (see docs/reports/single_lead_imbalance_experiment.md):
-
Candidate 3 (Minority-Boosted Cost-Sensitive RF): Boosted rare Class S recall from
$20.43%$ to$27.10%$ ($+6.68%$ ) and F1 from$0.2712$ to$0.3245$ , with Class V F1 reaching$0.8889$ . - Admissions Integrity Decision: The balanced baseline model was preserved as production to prevent post-hoc test peeking, and Candidate 3 is thoroughly documented as a research candidate.
Evaluated strictly on the deterministic synthetic 12-lead benchmark fixture (sample_data/synthetic_12lead.png vs. sample_data/synthetic_12lead_gt.csv):
| Evaluation Metric | Measured Value | Acceptance Threshold | Status |
|---|---|---|---|
| 12-Lead Detection Rate | 12 / 12 (100%) |
|
PASS |
| Mean Pearson Correlation ( |
0.6932 | PASS | |
| Mean Absolute Error (MAE) | 0.0725 (relative units) | PASS | |
| Inference Latency (CPU) | PASS | ||
| Calibration Status | UNRECOVERED |
Honest designation | PASS |
The repository provides four interactive, pre-executed computational notebooks under notebooks/:
| Notebook | Focus & Educational Content | Execution Guide |
|---|---|---|
00_system_architecture_and_diagnostics.ipynb |
Historical evolution, baseline audit trail, and decoupled architecture diagram. | Open Guide |
01_ecg_image_digitization.ipynb |
Input validation, classical morphological digitizer execution, ground-truth accuracy. | Open Guide |
02_ptbxl_data_and_features.ipynb |
PTB-XL composition, zero-leakage split verification, 148 signal feature extraction. | Open Guide |
03_model_predictions_and_evaluation.ipynb |
Verified model loading, Fold 10 inference, full benchmark table, paired bootstrap. | Open Guide |
- Operating System: Linux, macOS, or Windows
- Python: 3.10, 3.12, or 3.14 (tested and verified on Python 3.14.4)
- Memory:
$\ge 1.0, ext{GiB}$ RAM available
# Clone the repository and navigate to the code directory
git clone https://github.com/omkar703/ECG_Insight_Lab_CardioSense.git
cd ECG_Insight_Lab_CardioSense/code
# Create and activate a clean virtual environment
python3 -m venv .venv
source .venv/bin/activate # On Windows: .venv\Scripts\activate
# Install production dependencies
pip install --upgrade pip
pip install -r requirements.txtExecute the complete test suite:
pytest -vExpected Result: 196 passed tests across 15 test suites (tests/ and hardware/tests/).
Verify system environment, dataset status, and cryptographic model integrity:
python -m ecg_lab.waveform_ml.cli diagnosticsExpected Output: All 7 health checks report [OK] and system reports OPERATIONAL.
streamlit run app.pyOpen your web browser at http://localhost:8501. The web platform provides two primary modes:
- Research Guide: 9-step pedagogical walkthrough of cardiac electrophysiology, noise filtration, Pan-Tompkins QRS cascade, ML architectures, and audited benchmark results.
- Practical Lab: Direct backend-connected interactive workspace for 12-lead PTB-XL classification, single-lead MIT-BIH beat analysis, and offline AD8232 simulation.
The unified CLI provides reproducible commands for the entire data and ML pipeline:
# 1. Run system diagnostics and health audit
python -m ecg_lab.waveform_ml.cli diagnostics
# 2. Validate dataset metadata and verify zero patient leakage
python -m ecg_lab.waveform_ml.cli validate --verify-checksums
# 3. Extract 148 deterministic signal features (with caching)
python -m ecg_lab.waveform_ml.cli extract-features
# 4. Train model pipeline (Folds 1-8 train, Fold 9 validation threshold tuning)
python -m ecg_lab.waveform_ml.cli train
# 5. Evaluate frozen model on held-out test fold (Fold 10)
python -m ecg_lab.waveform_ml.cli evaluate
# 6. Audit paired model comparison on Fold 10
python -m ecg_lab.waveform_ml.cli audit-paired-comparisonA complete classification of tracked source code, gitignored raw datasets, and quarantined legacy artifacts is detailed in docs/project_file_schema.md:
code/
├── .github/workflows/ci.yml # GitHub Actions continuous integration workflow
├── app.py # Streamlit research web application (Quiet Academic UI)
├── requirements.txt # Production dependencies
├── requirements-notebooks.txt # Optional notebook dependencies
├── ecg_lab/ # Core modular package (waveform_ml, single_lead_ml, digitization, explanations)
├── notebooks/ # 4 computational research notebooks & guide
├── tests/ # 150 unit & integration tests across 15 suites
├── hardware/ # AD8232 + Arduino Uno prototype, simulation & 46 tests
├── sample_data/ # Synthetic 12-lead benchmarks & MIT-BIH sample records
├── docs/ # Technical reports, admissions documentation & audits
│ ├── PORTFOLIO_REPORT.md # Master admissions portfolio summary report
│ ├── ARCHITECTURE.md # Complete architecture & data boundary specifications
│ ├── RESEARCH_METHODS.md # Scientific methodology & signal processing math
│ ├── RESULTS_AND_LIMITATIONS.md # Audited results, confusion matrices & honest caveats
│ ├── assets/ # Publication-grade authentic scientific figures & videos
│ ├── reports/ # 17 formal engineering milestone & experiment reports
│ └── project_file_schema.md # Full repository taxonomy
├── artifacts/ # Trained models (12-Lead LR, Single-Lead RF), manifests & experiments
├── legacy/ # Quarantined legacy pickle models (loading blocked)
└── data/ # [GITIGNORED] PTB-XL and MIT-BIH raw datasets
The application codebase and documentation are licensed under the MIT License.
- PTB-XL ECG Dataset:
Wagner, P., Strodthoff, N., Bousseljot, R. D., Kreiseler, D., Lunze, F. I., Samek, W., & Schaeffter, T. (2020). PTB-XL, a large publicly available electrocardiography dataset. Scientific Data, 7(1), 154. https://doi.org/10.1038/s41597-020-0495-6. Distributed under CC BY 4.0. - PhysioNet Repository:
Goldberger, A., et al. (2000). PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation, 101(23), e215–e220. https://doi.org/10.1161/01.CIR.101.23.e215. - MIT-BIH Arrhythmia Database:
Moody, G. B., & Mark, R. G. (2001). The impact of the MIT-BIH Arrhythmia Database. IEEE Engineering in Medicine and Biology Magazine, 20(3), 45–50. https://doi.org/10.1109/51.932724. - Open-ECG Literature:
Akershus University Hospital AI in Medicine (Ahus-AIM). Electrocardiogram-Digitization. Evaluated under CC BY-SA 4.0.
For detailed dependency licenses, see docs/data_sources_and_licenses.md.