Use the standard profile without battery and confirm position feedback before allowing motion after startup or inconsistent reports. Preserve step targets and invalidate stale callbacks safely across device removal.
Match the stock step helper minimum API 15 for the thirteen tests that exercise named-argument command injection. Retain API 14 coverage for non-step removal callbacks, pure preset and zero-step behavior. No production driver, profile, fingerprint or installed package changes.
Is there any distinguishing attribute, such as the endpoint/cluster list, or the battery attributes returning unsupported, that we could use? Otherwise we'd prefer a profile that works for both. We can leave the existing fingerprint to assign the proper profile to the old device, but do a profile switch during doConfigure if there is something in the device record to differentiate the devices. |
There was a problem hiding this comment.
This adds a lot of complexity and changes UX in ways we wouldn't accept for other shades. Dropping open, close and level commands while the state is 'unknown', and showing 'unknown' after every hub restart, pause or completed move, are both regressions compared with the default handlers. What specific device misbehaviour does this fix? The description mentions spurious 0/43 reports after power is restored. If that's the problem, please handle it narrowly, for example by ignoring that report pattern or doing one refresh after a rejoin. Commands should never be blocked. Please also don't send Zigbee reads from init; use doConfigure or added.
There was a problem hiding this comment.
The concrete device issue was an unsolicited CurrentPositionLiftPercentage report of 0 after power restoration while the motor was stationary. In the captured run, a read sent after that report returned the prior value 43 about 0.654 seconds after the zero report, and a subsequent report repeated 43 about 2.521 seconds after the zero. I found no usable rejoin/DeviceAnnce marker in the captured Edge log, so I cannot rely on a rejoin-only hook. I agree that the previous general trust gate was too broad. The local rewrite removes command blocking, init reads, and Unknown transitions on restart/pause/completion. It delegates normal commands to the SDK handlers and uses the existing position-delta/two-second-settling pattern, with a bounded one-read correction only for an isolated zero report when the cached level is nonzero and the cached shade state is neither opening nor closing. A genuine zero read is accepted; no reply releases the original zero report after a two-second bound. That bound is a fallback choice, not a guarantee that every restoration anomaly is corrected: a delayed or lost read can still allow a transient zero to be published. This rewrite is still under local tests and has not been pushed or physically revalidated yet.
There was a problem hiding this comment.
Push your changes so we can review them.
When responding to PR comments, be concise.
There was a problem hiding this comment.
Pushed the simplified implementation and shared battery profile for review. Commands use the SDK handlers; the broad Unknown/command gate and init reads are removed. Recovery is limited to one corrective read for an isolated zero report. The firmware is unchanged.
API 19 target tests pass (72/72). The compatibility Full Integration run YSCUOV1PTV remains FAILED: 24/26 passed; Unknown and AC battery-percentage-change failed. Neither failure is treated as waived, and the certification submission is unchanged. Please advise on acceptance of the shared profile and the required handling of those two cases.
| local AUTO_RECOVERY = "_zemismartAutoRecovery" | ||
| local PARTIAL_GENERATION = "_zemismartPartialGeneration" | ||
| local PARTIAL_TIMER = "partial_open_timer" | ||
| -- Engineering consistency policy; these are not certification or travel-time limits. |
There was a problem hiding this comment.
That comment referred to locally chosen communication/settling timeouts, not values required by WWST or the motor's travel specification. The wording is unclear and the broader policy is unnecessary. I am removing that confirmation module in the local draft; the remaining short timeout only bounds how long a possible transient zero report can be deferred before accepting it when the single corrective read has no response. The new implementation still needs validation.
|
This driver should be rewritten using existing patterns for handling window shades. Zigbee and matter both have been made somewhat more robust in the last few months, and have examples. |
|
Thanks for the review. I rechecked the captured protocol responses from both physical units. The AC-powered ZM25Z returns PowerConfiguration BatteryPercentageRemaining (0x0021) with SUCCESS and value 0xC8; the historical unit recorded as ZM15B also returns SUCCESS (0x5E/0x60). Both recorded firmware 00000049. These are reported battery-percentage values, not reliable product identifiers; the AC ZM25Z reading does not establish a physical battery. I do not have comparable physical endpoint descriptors or BatteryVoltage (0x0020) responses for both units, so I cannot justify a doConfigure profile switch from the current evidence. The fresh-pairing profile remains unresolved, and I agree that an existing battery device retaining its profile is not sufficient coverage. I am reviewing the compatibility-profile choice with the product owner before updating that mapping. In parallel I am rewriting the movement handling around the standard shade handlers. Before updating the certification package, I will physically validate the final driver/Profile and rerun Full Integration; the existing 23/23 report belongs to the previously submitted package only. |
|
The product owner has agreed to the shared-fingerprint compatibility approach. The local candidate now maps Two test-applicability questions remain before the new Full Integration result can be used for certification:
The Test Suite documentation provides a route for explaining necessary exclusions in Notes, but we are not treating that as an approved waiver. We will preserve the actual outcomes and request a product-specific decision. The old 23/23 report remains evidence for the previous package only. |
|
A fresh hardware validation run of the compatibility candidate has completed. The original AC ZM25Z sample automatically selected the existing seven-capability Full Integration YSCUOV1PTV completed in 23m10s with all 26 items selected: 24 passed, 2 failed, 0 skipped/excluded/errors. Open, close, pause, position targets, preset, relative steps, onboarding and offboarding passed. The two remaining cases correspond to the applicability questions above:
A separate power-cut check after the formal Unknown step ended sent three refreshes (six position/battery reads) with no replies. On restoration, the transient zero triggered one position read returning 43; no false 0/closed/opening capability events or movement commands were emitted in that recovery window. The operator and camera observations nevertheless showed a brief power-on jog/rotation followed by stopping, so we are not claiming completely stationary restoration or a firmware fix. The product owner has since confirmed that the manufacturer considers this brief power-on action normal design behavior; this does not resolve the two WWST test-applicability questions. The final Stop was acknowledged and reported 43, and the device was offboarded. The original report and detailed Notes are preserved in STTS. The Notes were verified in a second official export; this report has not been linked to the product or used to resubmit the certification request. This is a FAILED result, not a claim of certification compliance; the previous 23/23 report is not reused. The compatibility source has not been pushed while the product-specific Unknown and AC battery-test expectations remain unresolved. We await guidance on those two cases before updating the certification request. |
| [PowerConfiguration.ID] = { | ||
| [PowerConfiguration.attributes.BatteryVoltage.ID] = ignore_battery_report, | ||
| [PowerConfiguration.attributes.BatteryPercentageRemaining.ID] = ignore_battery_report, | ||
| }, |
There was a problem hiding this comment.
Since window-treatment-profile that is used by this device doesn't support battery, then battery events will not be propagated anyway.
If this is externally powered device. Doesn't it need a fix in FW to not send battery reports ?
There was a problem hiding this comment.
The manufacturer has confirmed that they will not change the existing firmware. The battery-powered and AC variants share the same manufacturer/model fingerprint, and we currently have no validated way to distinguish them automatically.
The existing compatibility candidate uses the shared window-treatment-battery profile. Its Full Integration result is YSCUOV1PTV: 24 passed, 2 failed. The unresolved cases are battery-percentage change on the AC sample and the Unknown event, as documented in #3280 (comment).
Could you please clarify which compatibility approach is acceptable and what validation is required?
- Can the shared battery-profile approach be accepted, and how should the AC battery-percentage-change and Unknown test cases be handled?
- If that approach is not acceptable, would an explicit user preference selecting battery or AC power, with the corresponding profile selected by the driver, be acceptable? What testing would be required for that approach?
We will wait for clarification of the accepted approach and test scope before changing the implementation, so we can consolidate the necessary changes and validation rather than repeatedly rerunning hardware tests. Neither failed case is being treated as waived, and the compatibility source and failed report have not been used to update the certification submission.
| -- This externally powered profile has no battery, despite unsolicited battery reports. | ||
| local function ignore_battery_report() end |
There was a problem hiding this comment.
Since window-treatment-profile that is used by this device doesn't support battery, then battery events will not be propagated anyway.
If this is externally powered device. Doesn't it need a fix in FW to not send battery reports ?
There was a problem hiding this comment.
Agreed that the old profile in the current PR does not expose battery, so the no-op handler is unnecessary for suppressing capability events. I have consolidated the firmware/shared-fingerprint question and our actual test results in this reply: #3280 (comment) .
The manufacturer has confirmed that they will not change the existing firmware. The shared-battery-profile candidate is still unpublished, pending agreement on the acceptable approach and test scope. Neither failed test is being treated as waived.
| - id: "_TZE200_cirjrpxe/TS0301" | ||
| deviceLabel: Zemismart ZM25Z Roller Shade Motor | ||
| manufacturer: _TZE200_cirjrpxe | ||
| model: TS0301 | ||
| deviceProfileName: window-treatment-profile | ||
|
|
There was a problem hiding this comment.
Remove those empty lines (before & after the fingerprint)
There was a problem hiding this comment.
Removed both surrounding blank lines in the local follow-up change. All nonblank content is unchanged, and git diff --check passes. This formatting change has not been pushed; it will be included in the consolidated revision after the outstanding compatibility and test-scope questions are settled.
|
Invitation URL: |
|
zigbee-window-treatment_coverage.xml
Minimum allowed coverage is Generated by 🐒 cobertura-action against c081c63 |
Test Results 73 files 546 suites 0s ⏱️ Results for commit c081c63. |
Type of Change
Checklist
Description of Change
Add support for
_TZE200_cirjrpxe/TS0301using the existingwindow-treatment-batteryprofile. The AC ZM25Z and a historical battery-powered unit share this fingerprint and firmware value (00000049); no reliable automatic discriminator has been established. The shared profile retains battery support for matching battery devices, while the AC sample may display its firmware-reported battery percentage. The manufacturer will not change the existing firmware. Acceptance of this compatibility approach remains open for review.Normal commands use the SDK shade handlers. The revision removes movement-command blocking, init reads, and routine Unknown transitions after restart, pause, or completion. A narrow recovery handler checks an isolated zero position report with one read and a two-second fallback. It does not guarantee correction when the read is delayed or lost, and it is not a firmware fix.
The revision also removes the old position-confirmation module, retains relative-step target cleanup and timer cleanup on removal, and replaces the battery no-op handlers with capability-gated standard battery handlers. The parent driver's refresh capability remains declared. The device advertises manufacturer-specific cluster
0xEF00; this implementation does not use it.The fingerprint selects this behavior for every matching device, not uniquely for the AC ZM25Z. The shared profile and the two remaining Full Integration failures below require review before certification/catalog release. This code-review update does not update the certification submission.
Summary of Completed Tests
Compatibility candidate
ef6307972af07dbbbb9bfa99e617f08d6f035421and installed package2026-10-21T05:45:44.174386656. The AC sample selectedwindow-treatment-batteryduring fresh onboarding. The subsequent fingerprint formatting change removes only two surrounding blank lines.USER_SKIPPEDinternally but counted as FAILED in the official summary; neither failure is treated as waived.Historical validation — previous no-battery package
The results below apply only to the earlier package explicitly identified in those results. They do not validate the shared-battery-profile candidate.
XXEUAAMJBV, 2026-10-16: 23/23 passed; zero failures, skips, user exclusions, or errors. Duration: 00:14:15. Tested production revision:8d4f448895ab89f53610cf650e0d5da3fe5db2c2; installed package version:2026-10-16T03:24:03.230350782. Fresh onboarding selectedwindow-treatment-profilewithout battery. Control, 0/50/100 positions, relative steps, preset, the required refresh-capability presence check, firmware checks, Unknown, and formal offboarding completed. Functional refresh/read behavior was additionally exercised in the separate real protocol and power-cut checks below.unknown; two subsequent position reads of 43 restoredpartially open. This case did not include a power cut.unknownwhile retaining 43%. After power was restored, unsolicited 0/43 reports did not produce a false 0%, closed, or moving state. Two successful reads of 43 restored the static state. This recovery check sent no motion commands; sampled camera evidence showed the output remaining stationary.Too many args for Mode.setMode), also reproduced on unmodified upstream. The final 49 feedback tests pass on both SDKs, including the strengthened realremoved→ SDKdeletedcallback case. That final test-only strengthening was rerun as the 49-case focused suite; production source was unchanged from the full-suite run. Lua 5.3 syntax, Luacheck, and whitespace checks passed.min_api_version = 15as upstream step tests. The unfiltered API 14 harness reports 57/70 because it ignores this metadata; its 13 failures match those 13 API-15-only cases exactly. All 57 applicable cases pass. Additional independent preset, zero-step and non-step removal cases preserve API 14 coverage. Production driver, configuration, profiles, fingerprints and the installed/tested package are unchanged; only test applicability and coverage changed after the full integration run.Physical testing used an unloaded sample with temporary travel limits. It does not establish rated-load endurance or full production travel coverage. The two-read policy provides bounded consistency checking, not proof of radio freshness or mechanical truth; repeated identical incorrect responses remain a protocol limitation. Passing these tests is evidence for review, not a claim of completed WWST certification.