Umbrella for everything about PSF stars: how they are selected, how they are measured, and how well the PSF model matches them. The problems below are probably connected, so this issue keeps them in one place. The star verification tests are tracked separately in #765.
Why they belong together. In many exposures, stars come out about 1% larger than the PSF model (#956). On sub-0.5″ exposures, PSFEx sampling leaves a g1 residual (#989). Stars leak into the galaxy sample at low photo-z. The PSF-leakage fit needs a seeing-dependent β (sp_validation#452). These may all be one PSF-model problem. A pure, well-understood star sample is the first step to telling them apart, so selection comes first.
Selection (which objects train and validate the PSF model)
- PSF star selection: survey other surveys' methods (MU_MAX−MAG_AUTO, colour) #950: survey other surveys' selections (DES Y6, KiDS, HSC, Euclid); colour and MU_MAX−MAG_AUTO as alternatives to FWHM
- Faint limit for PSF stars: FWHM stops separating stars from galaxies past ~21 mag #935: FWHM stops separating stars from galaxies fainter than ~21 mag
- PSF star selection: apply the manual mask; M33 shows outlier rejection fails where contaminants dominate #993: M33 contaminates the sample; apply the manual mask (bit 8)
- Star-catalogue depth (r<22→r<23) and PSF-selection bias from flux-radius cut #840: star-catalogue depth and the flux-radius cut
- Pin PSFEx's compiled-in SAMPLE_* candidate cuts explicitly in default.psfex #919, PSFEx sample selection behavior #316: PSFEx applies its own compiled-in
SAMPLE_*cuts on top of ours
PSF model against stars
- Tentative: PSFEx models ~0.4% larger than stars on P3 tiles (worth exploring) #956: PSFEx models ~0.4% larger than stars
- PSFEx native sampling leaves a g1 residual on sub-0.5″ exposures; PSF consumers assume PSF_SAMP = 1 #989: PSFEx native sampling and sub-0.5″ seeing
- PSFEx validation catalogue: ACCEPTED compares unrelated numberings #980: the
ACCEPTEDcolumn of the validation catalogue carries no information - MCCD: restore to PSFEx parity #674, MCCD on a small DR6 area after the PSFEx production run (proposal) #972: MCCD as an alternative model
Star measurement
- ngmix: the reduced-χ² anomaly on stars (error model) #769: ngmix reduced-χ² anomaly on stars
- ngmix PSF fitter: drop the galaxy prior, adopt a metadetect-style dedicated PSF fit #778: a dedicated ngmix PSF fit without the galaxy prior
Star catalogue code and products
- [NEW FEATURE] diagnostics on setools star catalogue #585: setools diagnostics
- Latent defects in setools star merge, breakdown grid, create_final_cat and footprint resume #959: latent defects in the setools star merge
- Seed for random in SETools [BUG] #659: random seed in SETools
- Run 2: keep the products the additive B-mode search needs (star stamps, per-epoch shapes) #1001: keep star stamps and per-epoch shapes in run 2
Where to start. Selection work (#950) is the entry point and can be done by one person independently of the rest. A prototype that purifies the current candidates with PhotoPipe colours, unWISE and Gaia is on #950: 3–4% of PSF stars are contaminants, and the PSF is chromatic (−0.7% in size per magnitude of g−i) while the PSFEx model is not.
Claude Opus 5.5 on behalf of Cail
Activity
[-]Star & PSF measurement quality[/-][+]PSF stars: selection, measurement and model quality (umbrella)[/+]